The methane (CH₄) gas sensor can be integrated into fixed gas detection equipment, portable gas detectors, industrial monitoring instruments, and gas alarm systems. Users can select the 0-5% Vol or 0-100% LEL range according to the application requirements. Its compact sensor design makes it suitable for OEM gas detection equipment and continuous methane monitoring systems.

Methane Sensor with 0 to 5% Vol / 0–100% LEL Range

High Accuracy and Long-Term Stability
The methane (CH₄) gas sensor is designed for methane concentration monitoring in coal mines, natural gas pipelines, industrial plants, and confined spaces. It is suitable for gas leak detection, environmental monitoring, and industrial safety applications.
| Model | SISCO-GS-CH4-100 |
| Working Voltage | 3.3 ~ 5 V DC |
| Operating Temperature | -20 ~ 60 °C, -40 ~ 70 °C (Extended) |
| Storage Temperature | 0 ~ 40 °C (Recommended) |
| Weight | 16.5 g |
| Service Life | 5 years |
| Target Gas | Methane (CH₄) |
| Measuring Range | 0 ~ 5% Vol (0 ~ 100% LEL) |
| Resolution | 50 ppm |
| Preheating Time | ≤10 s |
| Linearity | ±3% Full Scale or ±5% of Reading |
| Long-Term Stability | ±2% Full Scale or ±5% of Reading |
| Temperature Characteristics | ±2% Full Scale or ±10% of Reading @ -20 to 50 °C; ±4% Full Scale or ±20% of Reading @ Other Operating Temperatures |
| Humidity Characteristics | ±2% Full Scale or ±15% of Reading Relative to 25% RH |
| Automatic Calibration | 168 Hours (Default); Can Be Enabled or Disabled According to Actual Application Requirements |
| Baud Rate | 9600, 19200, 38400, 57600 (Default) |
| Output | Digital Output or Industrial 0.4 to 2 V Output; Unit: ppm; Temperature-Compensated Linear Signal |
| Operating Current | Average Current <1 mA; Peak Current <10 mA |
| Operating Humidity | 0 ~ 95% RH (Non-Condensing) |
| Operating Pressure | 800 ~ 1200 mbar |
| Optical Coating | High-Reflectivity Gold-Plated Layer |

Q1: What is the measurement range of the Methane (CH4) Gas Sensor?
A1: The Methane (CH4) Gas Sensor is available with a measurement range of 0–5% Vol or 0–100% LEL, depending on the selected model or application. It is designed for methane concentration monitoring in industrial and environmental gas detection systems.
Q2: Does the methane sensor respond to other gases?
A2: The methane sensor features high selectivity to methane (CH₄) and is designed to respond specifically to methane while minimizing interference from other gases.
Q3: Does the methane sensor require regular calibration?
A3: The methane sensor features excellent zero stability with no zero drift and does not require calibration during its service life under normal operating conditions.
Tips: What is the difference between 0–5% Vol and 0–100% LEL for methane detection?
% Vol indicates the actual methane concentration by volume, while % LEL indicates the percentage of methane's Lower Explosive Limit. For methane, 100% LEL is approximately 5% Vol, so a 0–5% Vol range corresponds approximately to 0–100% LEL.
Thank you for buying industrial test and measurement equipment on SISCO.com, all products sold by SISCO and the partner cover a 12 months warranty, effective from the date of receiving the products.
SISCO is responsible for providing free spare parts, and free technical support to assist the customer to repair the defective products until the problem is solved.