This SF6 gas sensor offers two measurement ranges, 0–500 ppm and 0–1000 ppm, to meet different gas monitoring requirements. Multiple output options, including RS485, 4–20mA, 0–5V, and 0–10V, allow easy integration with PLCs, industrial control systems, and remote monitoring equipment.

Harsh Environment Resistance

Fast Response and Anti-Interference
| Model | SISCO-GS-SF6-3002 |
| Power Supply | 10~30V DC |
| Average Power Consumption | 0.95W |
| Output Signal | RS485/4-20mA/0-5V/0-10V (optional) |
| SF6 Resolution | 1ppm |
| Maximum Allowable SF6 Error | ±10% |
| SF6 Measurement Range | 0~500ppm/0~1000ppm (optional) |
| Zero Drift | ±3ppm |
| Operating Temperature | -20~50°C |
| Operating Humidity | 15~90%RH, no condensation |
| Stability | ≤2% signal value/month |
| Response Time | ≤30s |
| Preheat Time | ≥30min |
| Repeatability | ≤3% kPa |
| Pressure Range | 90~110 kPa |

| SF6 Transmitter | Wire Color | Description |
| Power | Brown | Power + (10~30V DC) |
| Black | Power - | |
| Communication | Yellow | 485-A |
| Blue | 485-B |

Installation Notes: Since sulfur hexafluoride (SF6) is denser than air, the transmitter should be installed as close to the ground as possible.
Q1: What measuring ranges are available for the SF6 gas transmitter?
A1: The SF6 gas transmitter offers two optional measuring ranges: 0–500 ppm and 0–1000 ppm, suitable for different SF6 gas concentration monitoring requirements.
What factors affect the accuracy of SF6 gas concentration measurements?
Q2: What factors affect the accuracy of SF6 gas concentration measurements?
A2: Measurement accuracy can be affected by installation conditions, environmental temperature, humidity, and proper calibration. Following the recommended installation guidelines helps maintain reliable SF6 gas monitoring performance.
Q3: Where should an SF6 gas transmitter be installed in a power substation?
A3: For indoor SF6 leak monitoring, the transmitter is generally installed near the floor because SF6 gas is heavier than air and tends to accumulate in lower areas. Installation locations should also consider ventilation, potential leakage points, and equipment layout.
Tips: Can an SF6 gas transmitter connect to a PLC or remote monitoring system?
Yes. The SF6 gas transmitter supports multiple output options, including RS485, 4–20mA, 0–5V, and 0–10V, allowing flexible connection to compatible PLCs, industrial control systems, data acquisition equipment, and remote gas monitoring systems. These signal options enable real-time SF6 concentration data transmission, centralized monitoring, and integration with existing automation systems for continuous gas detection and safety management.
Thank you for buying industrial test and measurement equipment on SISCO.com, all products sold by SISCO and the partner cover a 12 months warranty, effective from the date of receiving the products.
SISCO is responsible for providing free spare parts, and free technical support to assist the customer to repair the defective products until the problem is solved.