All Categories
    Menu Close

    1 inch Electronic Turbine Meter for Water/Methanol/Fuel

    High-accuracy electronic turbine flow meter with a nominal size of 1 inch, minimum flow of 10L/min, maximum flow of 100 L/min, 0.6 Mpa maximum working pressure. The turbine meter has a high-definition LCD display which has four units of measurement can be switched.
    SKU: SISCO-FM-KE24
    *
    $65.46
    i h
    🚚 Free shipping
    🔙 30-day returns
    📅 Delivery: 7-12 days
    Overview


    SISCO 1-inch turbine meter for sale. The digital turbine flow meter uses turbine metering to measure flow more accurately, two colors black or white can be chosen. The electronic turbine meter is widely used to measure most pure and stable liquids such as water, methanol and fuel.

    Electronic turbine meter detail

    The turbine meter design with a high-definition LCD display

    • The high-definition LCD provides sharp, easy-to-read measurements, even in low-light conditions, ensuring accurate monitoring at a glance.
    • The intuitive display layout allows users to easily navigate through different settings and view real-time flow data, including total volume, flow rate, and diagnostic information.
    • Users can adjust the display settings to show different units of measurement or select specific data points to be highlighted, making the digital turbine flow meter versatile for different applications.
    Electronic turbine meter detail

    Turbine metering, a more accurate flow

    • The turbine mechanism ensures highly accurate flow measurements by converting the rotational speed of the turbine directly into precise flow data, making it ideal for applications requiring exact fluid control.
    • With its ability to maintain stable readings across a wide range of flow rates, the turbine flow meter delivers consistent accuracy, ensuring that even slight variations in flow are reliably captured.
    • The electronic turbine meter is suitable for stable and clean liquids, the turbine flow meter minimizes the impact of turbulence and fluid viscosity on the measurement, resulting in more precise and reliable flow data.

    Dimension

    Electronic turbine meter sizes

    Application

    SISCO flow meter calculates the mass flow rate of the fluid based on the power required to maintain the constant temperature difference. Thermal mass flow meters are commonly used in applications where precise measurement of gas flow is required, such as in biotechnology, medical equipment, scientific research, chemical and petrochemical industry.

    Flow meter for medical equipment

    Medical Equipment

    Flow meter for scientific research

    Scientific Research

    Flow meter for petrochemical industry

    Petrochemical Industry

    Flow meter for biotechnology

    Biotechnology

    Specs

     

    Model SISCO-PM-KE24
    Nominal Diameter 1 inch
    Minimum Flow 10 L/min
    Maximum Flow 100 L/min
    Connection Method External thread connection
    Applicable Media Water, oil, urea, methanol
    Unit of Measurement QTS, PTS, L, GAL
    Measurement Accuracy ±1%
    Maximum Working Pressure 0.6 Mpa
    Material Aluminum alloy, PPS plastic, etc.
    Single Measurement Range 99999
    Cumulative Measurement Range 299999999
    Weight 0.215 kg


    Detail

    Electronic turbine meter detail

    FAQs

    Q1: What is a flow meter?
    A1: A flow meter is a device that measures the flow rate or volume of a fluid, such as a liquid or gas, as it moves through a pipe or conduit. It provides real-time data on the amount of fluid passing a specific point, which is crucial for monitoring and controlling industrial processes, ensuring accurate dosing, and optimizing system performance. Flow meters come in various types and technologies, each suited for different applications and fluid properties.

    Q2: How often should flow meters be calibrated?
    A2: The frequency of flow meter calibration depends on several factors, including:

    1. Application Requirements: High-precision applications may require more frequent calibration.
    2. Fluid Type: Corrosive or abrasive fluids may necessitate more regular checks.
    3. Operating Conditions: Extreme temperatures, pressures, or high flow rates can affect accuracy.
    4. Manufacturer Recommendations: Follow the guidelines provided by the flow meter manufacturer.
    5. Regulatory Standards: Some industries have specific calibration requirements.

    As a general rule, flow meters are often calibrated annually, but this can vary. It’s also advisable to calibrate whenever there is a significant change in process conditions or if the flow meter shows signs of drift or performance issues.

    Q3: What factors can affect flow meter accuracy?
    A3: Several factors can affect the accuracy of a flow meter:

    • Fluid Properties: Changes in fluid density, viscosity, or temperature can impact accuracy. For instance, varying fluid densities can affect measurement, especially in vortex and electromagnetic flow meters.
    • Flow Conditions: Turbulence, flow profile, and pressure drops can influence measurements. Inaccurate readings can occur if the flow is not properly aligned with the meter.
    • Installation Issues: Incorrect installation, such as improper pipe alignment or insufficient straight pipe sections before and after the meter, can cause inaccuracies.
    • Temperature: Extreme temperatures can affect fluid properties and the meter's components, leading to measurement errors.
    • Pressure: Variations in pressure can alter fluid density and viscosity, impacting flow meter accuracy.

    Tips: Can the meter measure both flow rate and total volume?

    Yes, an electronic turbine meter is designed to measure both the flow rate and the total volume of liquid passing through it. The flow rate is monitored in real-time, providing immediate feedback on the current speed or volume per unit of time at which the liquid is flowing. This information is typically displayed on a digital screen, allowing for easy and precise monitoring.

    In addition to real-time flow rate measurement, the meter also accumulates the total volume of liquid that has passed through the system, displaying this cumulative total on the same digital interface. This dual functionality makes the electronic turbine meter particularly valuable in applications where it is essential to monitor ongoing fluid flow while also keeping a precise record of the total amount of liquid that has been transferred over time. This makes it ideal for use in industries like fuel management, water treatment, and chemical processing, where both real-time flow data and accurate volume totals are critical.

    Warranty

    Thank you for buying industrial test and measurement equipment on SISCO.com, all products sold by SISCO and the partner cover a 12 months warranty, effective from the date of receiving the products.


    What is covered?

    SISCO is responsible for providing free spare parts, and free technical support to assist the customer to repair the defective products until the problem is solved.


    What is not covered?

    • Product purchased from anyone other than a SISCO store or a SISCO authorized reseller.
    • Expendable parts.
    • Routine cleaning or normal cosmetic and mechanical wear.
    • Damage from misuse, abuse or neglect.
    • Damage from use of parts other than SISCO approved.
    • Damage from use outside the product’s usage or storage parameters.
    • Damage from use of parts not sold by SISCO.
    • Damage from modification or incorporation into other products.
    • Damage from repair or replacement of warranted parts by a service provider other than a SISCO authorized service provider.
    • Damage caused by the application environment not meeting the product usage requirements and the failure to perform preventive maintenance.
    0.0 0
    Write your own review Close
    *
    *