    Smart air quality sensor monitors CO2, CH2O, O2, CH4, CO, and other gases in real time. It supports RS485, 4-20mA, 0-10V, Bluetooth, and WiFi outputs for flexible system integration. The 100x100x30mm ABS housing enables easy wall or ceiling mounting. Wide DC 10-30V input ensures continuous operation. Precision sensing delivers stable readings with 1-second updates.
    SKU: SISCO-AQS-00802A
    *
    *
    $72.53
    i h
    🚚 Free shipping
    🔙 30-day returns
    📅 Delivery: 7-12 days
    Overview

     

    SISCO smart air quality sensor integrates multiple gas detection channels into a single compact unit. Various output interfaces simplify connectivity to existing equipment. Advanced circuitry maintains measurement accuracy over extended periods. Low-power design reduces operating costs. Plug-and-play architecture minimizes setup complexity.

    Smart Air Quality Sensor Back View

    Multi-Gas Monitoring with Modular Flexibility

    • Supports up to four core parameters in one compact unit, eliminating the need for multiple separate instruments.
    • Allows users to select and combine detection modules based on specific application requirements, avoiding unnecessary features and reducing overall cost.
    • Delivers stable readings with 1-second update intervals, ensuring continuous and timely air quality data.
    • Maintains measurement accuracy over extended periods without calibration drift, thanks to advanced signal processing circuitry.
    Smart Air Quality Sensor Detail View

    Versatile Output Interfaces for Seamless Integration

    • Standard RS485 (Modbus) output enables direct integration with PLC, DCS, and building automation systems commonly used in industrial environments.
    • Optional 4-20mA and 0-10V analog outputs provide compatibility with traditional control equipment requiring standard industrial signals.
    • Wireless interfaces including Bluetooth and WiFi allow easy connection to smart home gateways, mobile devices, and cloud platforms.
    • Plug-and-play architecture and flexible output selection simplify system design and reduce installation time without requiring additional signal converters.

    Applications

    SISCO smart air quality sensor serves HVAC systems, green buildings, smart offices, and environmental monitoring stations. Additional gas options extend to agricultural facilities, underground parking, and industrial safety applications where continuous air quality assessment is required.

    Smart Air Quality Sensor For Smart Office

    Smart Office

    Smart Air Quality Sensor For Smart Home

    Smart Home

    Smart Air Quality Sensor For Smart Agriculture

    Smart Agriculture

    Smart Air Quality Sensor For Green Building

    Green Building

    Specs

     

    Model SISCO-AQS-00802A
    Target Gases CO2/CH2O/O2/CH3/O3/NH3/SO2/CL2/H2/CO 
    Output Interfaces Modbus-RS485, 0-10V, 4-20mA
    Power Supply DC 10-30V (Standard 24V)
    Operating Current ≤200mA
    Update Rate 1 second (default)
    Warm-up Time ≤2 minutes
    Housing Material ABS Flame-Retardant
    Mounting Method Ceiling-Mounted, Wall-Mounted
    Dimensions 100 × 100 × 30 mm
    Operating Temperature -10°C ~ 50°C
    Operating Humidity 0-95% RH (No Condensation)
    Storage Temperature -20°C ~ 60°C
    Storage Humidity 0-99% RH (No Condensation)


    Dimensions (unit: mm)

    Smart Air Quality Sensor Dimensions

    FAQs

    Q1: How to read and interpret the data from this smart air quality sensor?
    A1: The sensor updates all gas readings every second. For CO2, levels below 1000ppm indicate good ventilation; CH2O below 0.08mg/m³ is considered safe; O2 should stay between 19.5%-23.5%Vol for human comfort; CH4 and CO readings above 10%LEL and 50ppm respectively, may trigger safety alerts. All data can be accessed via RS485, 0-10V, or 4-20mA outputs.

    Q2: What output options does this smart air quality sensor support for system integration?
    A2: Modbus-RS485 comes as standard, with 0-10V, 4-20mA, Bluetooth, and WiFi available as optional interfaces. These outputs enable direct connection to PLCs, building automation systems, IoT gateways, and mobile devices without extra converters.

    Q3: How should this smart air quality sensor be installed and powered?
    A3: Both wall-mounted and ceiling-mounted installations are supported. It operates on DC 10-30V (standard 24V), drawing < 200 mA, with a 2-minute warm-up time. The compact 100×100×30mm ABS housing fits most indoor environments.

    Tips: What should I consider when deploying this smart air quality sensor for accurate CO2, TVOC, HCHO, and PM2.5 monitoring?

    1. Allow at least 2 minutes of warm-up time after power-on before taking readings, as the sensor needs this period to stabilize and deliver accurate measurements.
    2. Avoid placing the sensor near direct airflow sources such as vents, fans, or open windows, as strong air movement may cause fluctuating or unrepresentative readings.
    3. Mount the sensor at breathing height (approximately 1.2–1.5 meters above floor level) for wall-mounted installation, as this represents the most relevant air quality level for human exposure.
    4. Perform periodic verification of measurement accuracy using calibration gas or comparison with a reference instrument to ensure long-term reliability.
    Warranty

    Thank you for buying industrial test and measurement equipment on SISCO.com, all products sold by SISCO and the partner cover a 12 months warranty, effective from the date of receiving the products.


    What is covered?

    SISCO is responsible for providing free spare parts, and free technical support to assist the customer to repair the defective products until the problem is solved.


    What is not covered?

    • Product purchased from anyone other than a SISCO store or a SISCO authorized reseller.
    • Expendable parts.
    • Routine cleaning or normal cosmetic and mechanical wear.
    • Damage from misuse, abuse or neglect.
    • Damage from use of parts other than SISCO approved.
    • Damage from use outside the product’s usage or storage parameters.
    • Damage from use of parts not sold by SISCO.
    • Damage from modification or incorporation into other products.
    • Damage from repair or replacement of warranted parts by a service provider other than a SISCO authorized service provider.
    • Damage caused by the application environment not meeting the product usage requirements and the failure to perform preventive maintenance.
    0.0 0
    Write your own review Close
    *
    *